Artifacts in the Electron Paramagnetic Resonance Spectra of C60 Fullerene Ions: Inevitable C120O Impurity

Published Web Location

https://doi.org/10.1021/ja011832f
Abstract

Aspects of the electron paramagnetic resonance (EPR) spectra of C60n- fulleride ions (n = 2, 3) and the EPR signal observed in solid C60 are reinterpreted. Insufficient levels of reduction and the unrecognized presence of C120O, a ubiquitous and unavoidable impurity in air-exposed C60, have compromised most previously reported spectra of fullerides. Central narrow line width signals ("spikes") are ascribed to C120On- (n = odd). Signals arising from axial triplets (g approximately 2.0015, D = 26-29 G) in the spectrum of C602- are ascribed to C120On- (n = 2 or 4). Their D values are more realistic for C120O than C60. Less distinct signals from "powder" triplets (D approximately 11 G) are ascribed to aggregates of C120On- (n = odd) arising from freezing nonglassing solvents. In highly purified samples of C60, we find no evidence for a broad approximately 30 G signal previously assigned to a thermally accessible triplet of C60(2-). The C60(2-) ion is EPR-silent. Signals previously ascribed to a quartet state of the C60(3-) ion are ascribed to C120O4-. Uncomplicated, authentic spectra of C60- and C60(3-) become available when fully reduced samples are prepared under strictly anaerobic conditions from freshly HPLC-purified C60. Solid off-the-shelf C60 has an EPR signal (g approximately 2.0025, DeltaH(pp) approximately 1.5 G) that is commonly ascribed to the radical cation C60*+. This signal can be reproduced by exposing highly purified, EPR-silent C60 to oxygen in the dark. Doping C60 with an authentic C60*+ salt gives a signal with much greater line width (DeltaH(pp) = 6-8 G). It is suggested that the EPR signal in air-exposed samples of C60 arises from a peroxide-bridged diradical, *C60-O-O-C60* or its decomposition products rather than from C60*+. Solid-state C60 is more sensitive to oxygen than previously appreciated such that contamination with C120O is almost impossible to avoid.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View