Skip to main content
Download PDF
- Main
Reverse total shoulder arthroplasty with proximal bone loss: a biomechanical comparison of partially vs. fully cemented humeral stems
Published Web Location
https://doi.org/10.1016/j.jse.2024.01.022Abstract
Background
The appropriate amount of cementation at the time of reverse total shoulder arthroplasty with significant proximal bone loss or resection is unknown. Extensive cementation of a humeral prosthesis makes eventual revision arthroplasty more challenging, increasing the risk of periprosthetic fracture. We analyzed the degree of subsidence and torque tolerance of humeral components undergoing standard cementation technique vs. our reduced polymethyl methacrylate (PMMA) protocol. Reduced cementation may provide sufficient biomechanical stability to resist physiologically relevant loads, while still permitting a clinically attainable torque for debonding the prosthesis.Methods
A total of 12 cadaveric humeri (6 matched pairs) underwent resection of 5 cm of bone distal to the greater tuberosity. Each pair of humeri underwent standard humeral arthroplasty preparation followed by either cementation using a 1.5-cm PMMA sphere at a location 3 cm inferior to the porous coating or standard full stem cementation. A 6-degree-of-freedom robot was used to perform all testing. Each humeral sample underwent 200 cycles of abduction, adduction, and forward elevation while being subjected to a physiologic compression force. Next, the samples were fixed in place and subjected to an increasing torque until implant-cement separation or failure occurred. Paired t tests were used to compare mean implant subsidence vs. a predetermined 5-mm threshold, as well as removal torque in matched samples.Results
Fully and partially cemented implants subsided 0.49 mm (95% CI 0.23-0.76 mm) and 1.85 mm (95% CI 0.41-3.29 mm), respectively, which were significantly less than the predetermined 5-mm threshold (P < .001 and P < .01, respectively). Removal torque between fully cemented stems was 45.22 Nm (95% CI 21.86-68.57 Nm), vs. 9.26 Nm (95% CI 2.59-15.93 Nm) for partially cemented samples (P = .021). Every fully cemented humerus fractured during implant removal vs. only 1 in the reduced-cementation group. The mean donor age in our study was 76 years (range, 65-80 years). Only 1 matched pair of humeri belonged to a female donor with comorbid osteoporosis. The fractured humerus in the partially cemented group belonged to that donor.Conclusion
Partially and fully cemented humeral prostheses had subsidence that was significantly less than 5 mm. Partially cemented stems required less removal torque for debonding of the component from the cement mantle. In all cases, removal of fully cemented stems resulted in humeral fracture. Reduced cementation of humeral prostheses may provide both sufficient biomechanical stability and ease of future component removal.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%