Skip to main content
Download PDF
- Main
Correlation between X-ray tube current exposure time and X-ray photon number in GATE.
Published Web Location
https://doi.org/10.3233/xst-221126Abstract
Background
X-ray image quality relies heavily on the emitted X-ray photon number which depends on X-ray tube current and exposure time. To accurately estimate the absorbed dose in an imaging protocol, it is better to simulate the X-ray imaging with a Monte Carlo platform such as GATE (Geant4 Application for Tomographic Emission). Although input of GATE is the X-ray photon number of the simulated X-ray tube, it lacks a good way to setup the photon number for a desired X-ray tube current setting.Objective
To provide a method to correlate the experimental X-ray tube current exposure time and the X-ray photon number in GATE.Methods
The accumulated radiation dose of a micro-computed tomography (CT) X-ray tube was recorded at different current exposure times with a general-purpose ion chamber. GATE was used to model the experimental microCT imaging system and calculate the total absorbed dose (cGy) in the sensitive volume of the ion chamber with different X-ray photon numbers. Linear regression models are used to establish a correlation between the estimated X-ray photon number and the X-ray tube settings. At first, one model establishes the relationship between the experimentally measured dose and the X-ray tube setting. Then, another model establishes a relationship between the simulated dose and the X-ray number in GATE. At last, by correlating these two models, a regression model to estimate the X-ray output number from an experimental X-ray tube setting (mAs) is obtained.Results
For a typical micro-CT scan, the X-ray tube is operated at 50 kVp and 0.5 mA for a 500 ms exposure time per projection (0.25 mAs). For these X-ray imaging parameters, the X-ray number per projection is estimated to be 3.613×106 with 1.0 mm Al filter.Conclusion
The findings of this work provide an approach to correlate the experimental X-ray tube current exposure time to the X-ray photon number in the GATE simulation of the X-ray tube to more accurately determine radiation dose for an imaging protocol.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%