- Main
Water Uptake and Proton Conductivity in Porous Block Copolymer Electrolyte Membranes
Published Web Location
https://doi.org/10.1021/acs.macromol.5b00950Abstract
We demonstrate that the water uptake and conductivity of proton-conducting block copolymer electrolyte membranes can be controlled systematically by the introduction of pores in the conducting domains. We start with a membrane comprising a mixture of homopolymer polystyrene (hPS) and a polystyrene-b-polyethylene-b-polystyrene (SES) copolymer. Rinsing the membranes in tetrahydrofuran and methanol results in the dissolution of hPS, leaving behind a porous membrane. The polystyrene domains in the porous SES membranes are then sulfonated to give a porous membrane with hydrophilic and hydrophobic domains. The porosity is controlled by controlling Φv, the volume fraction of hPS in the blended membrane. The morphology of the membranes before and after sulfonation was studied by scanning transmission electron microscopy (STEM), electron tomography, and resonance soft X-ray scattering (RSoXS). The porous structures before and after sulfonation are qualitatively different. Water uptake of the sulfonated membranes increased with increasing Φv. Proton conductivity is a nonmonotonic function of Φv with a maximum at Φv = 0.1. The introduction of microscopic pores in the conducting domain provides an additional handle for tuning water uptake and ion transport in proton-conducting membranes. (Graph Presented).
Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content