Clinical Effectiveness of CRT and ICD Therapy in Heart Failure Patients by Racial/Ethnic Classification Insights From the IMPROVE HF Registry
Published Web Location
https://doi.org/10.1016/j.jacc.2014.05.060Abstract
Background
Clinical trials have demonstrated benefit for cardiac resynchronization therapy (CRT) and implantable cardioverter-defibrillator (ICD) therapies in patients with heart failure with reduced ejection fraction (HFrEF); yet, questions have been raised with regard to the benefit of device therapy for minorities.Objectives
The purpose of this study was to determine the clinical effectiveness of CRT and ICD therapies as a function of race/ethnicity in outpatients with HFrEF (ejection fraction ≤35%).Methods
Data from IMPROVE HF (Registry to Improve the Use of Evidence-Based Heart Failure Therapies in the Outpatient Setting) were analyzed by device status and race/ethnicity among guideline-eligible patients for mortality at 24 months. Multivariate Generalized Estimating Equations analyses were conducted, adjusting for patient and practice characteristics.Results
The ICD/cardiac resynchronization defibrillator (CRT-D)-eligible cohort (n = 7,748) included 3,391 (44%) non-Hispanic white, 719 (9%) non-Hispanic black, and 3,638 (47%) other racial/ethnic minorities or race-not-documented patients. The cardiac resynchronization pacemaker (CRT-P)/CRT-D-eligible cohort (n = 1,188) included 596 (50%) non-Hispanic white, 99 (8%) non-Hispanic black, and 493 (41%) other/not-documented patients. There was clinical benefit associated with ICD/CRT-D therapy (adjusted odds ratio: 0.64, 95% confidence interval: 0.52 to 0.79, p = 0.0002 for 24-month mortality), which was of similar proportion in white, black, and other minority/not-documented patients (device-race/ethnicity interaction p = 0.7861). For CRT-P/CRT-D therapy, there were also associated mortality benefits (adjusted odds ratio: 0.55, 95% confidence interval: 0.33 to 0.91, p = 0.0222), and the device-race/ethnicity interaction was not significant (p = 0.5413).Conclusions
The use of guideline-directed CRT and ICD therapy was associated with reduced 24-month mortality without significant interaction by racial/ethnic group. Device therapies should be offered to eligible heart failure patients, without modification based on race/ethnicity.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%