Comparison of Ganglion Cell Layer and Inner Plexiform Layer Rates of Change in Suspected and Established Glaucoma.
Abstract
Purpose
We compared ganglion cell layer (GCL) and inner plexiform layer (IPL) rates of change (RoC) in patients with glaucoma suspect (GS) and established glaucoma (EG) to test the hypothesis that IPL thickness changes would occur earlier than GCL changes in eyes with early damage.Design
Prospective, cohort study.Methods
A total of 64 GS eyes (46 patients) and 112 EG eyes (112 patients) with ≥2 years of follow-up and ≥3 macular optical coherence tomography scans were included. GCL and IPL superpixel thickness measurements were exported. A Bayesian hierarchical model with random intercepts/slopes and random residual variances was fitted to estimate RoC in individual superpixels. Normalized RoC and proportions of superpixels with significantly negative and positive GCL and IPL RoC were compared within the groups.Results
The average (SD) follow-up time and number of scans were 3.5 (0.7) years and 4.2 (1.0), respectively, in the GS group and 3.6 (0.4) years and 7.3 (1.1) in the EG group. Mean (SD) normalized RoC was faster for GCL than IPL (-0.69 [0.05] vs -0.33 [0.04]) in the GS group, whereas it was faster for IPL (-0.47 [0.03] vs -0.28 [0.02]) in EG eyes. GCL RoC were significantly negative in 24 of 36 superpixels compared with 8 of 36 for IPL (P < .001) in GS eyes. In the EG group, 23 of 36 superpixels had significant negative IPL RoC compared with 13 of 36 superpixels for GCL (P = .006).Conclusions
GCL thickness is more likely to demonstrate change over time compared with IPL in glaucoma suspects. There is no evidence of preferential IPL thinning in eyes with suspected early glaucoma damage.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
If you recently published or updated this item, please wait up to 30 minutes for the PDF to appear here.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%