Skip to main content
eScholarship
Open Access Publications from the University of California

UCSF

UC San Francisco Previously Published Works bannerUCSF

Estimated GFR Accuracy When Cystatin C- and Creatinine-Based Estimates Are Discrepant in Older Adults.

Abstract

RATIONALE & OBJECTIVE: Serum creatinine and cystatin C are used to estimate glomerular filtration rate, but creatinine-based estimated glomerular filtration rate (eGFRcr), cystatin C-based estimated glomerular filtration rate (eGFRcys), and combined creatinine- and cystatin C-based estimated glomerular filtration rate (eGFRcr-cys) are often divergent, particularly in older adults. We investigated which estimated glomerular filtration rate (eGFR) was more accurate and less biased compared with measured glomerular filtration rate (mGFR). STUDY DESIGN: A diagnostic test study from the Berlin Initiative Study. SETTING & PARTICIPANTS: The study population included 657 individuals aged 70 years or older with iohexol plasma clearance (mGFR) and serum creatinine and cystatin C measurements: 567 community-dwelling participants and 90 with a serum creatinine of ≥1.5 mg/dL. TESTS COMPARED: We defined 3 groups on the basis of the difference eGFRcys - eGFRcr: whether < -5 mL/min/1.73 m2 (lower eGFRcys), within 5 mL/min/1.73 m2 (reference), or ≥ 5 mL/min/1.73 m2 (lower eGFRcr). eGFRcr, eGFRcys, and eGFRcr-cys were compared to mGFR to assess bias and accuracy. OUTCOME: Median bias (eGFR minus mGFR) with 95% CIs and accuracy (percentage of eGFR values within ±30% of mGFR). RESULTS: The mean ± standard deviation age was 78 ± 6 years; the mean eGFRcys, eGFRcr, and eGFRcr-cys were 59 ± 23, 64 ± 20, and 61 ± 22 mL/min/1.73 m2, respectively, and the mean mGFR was 56 ± 19 mL/min. Half of the participants were in the lower eGFRcys group (n=337, 51%). Among them, the median bias for eGFRcys was the lowest (median bias, -2.7; 95% CI, -3.8 to -1.9) compared with the other eGFR equations. Conversely, in the lower eGFRcr group (n=121, 18%), the median bias for eGFRcr was the lowest compared with those for eGFRcys and eGFRcr-cys (2.9; [95% CI, 0.9-4.8] vs 13.8 [95% CI, 11.4-15.6] and 9.5 [95% CI, 7.7-11.0], respectively). Accuracy (percentage of eGFR values within ±30% of mGFR) was 93% for eGFRcr in the lower eGFRcr group and 92% for eGFRcys and 94% for eGFRcr-cys in the lower eGFRcys group. LIMITATIONS: Untested generalizability in younger populations. CONCLUSIONS: Among older adults, the lower eGFR between eGFRcys and eGFRcr was a more accurate and less biased estimate of mGFR when comparing the groups.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View