- Bhattacharya, Debika;
- Winnett, Alexander;
- Fulcher, Jennifer A;
- Sohn, Linda;
- Calub, Feliza;
- Lee-Chang, Ian;
- Schwartzman, William A;
- Beenhouwer, David O;
- Vallone, John;
- Graber, Christopher J;
- Goetz, Matthew B
Abstract
Background
Despite numerous outbreaks, antibody responses to SARS-CoV-2 in residents of skilled nursing facilities (SNF) are not well described. We reviewed serological test results in a cohort of SNF residents who had been repetitively screened for SARS-CoV-2 infection by nasopharyngeal swab PCR.
Methods
In late March 2019, we identified symptomatic SARS-CoV-2 PCR positive residents at a SNF. In response, all remaining SNF patients were serially screened, and all SARS-CoV-2 PCR positive patients were transferred to the acute care hospital or cohorted in a separate COVID Recovery Unit (CRU) in the SNF. In early June, all SNF residents (SARS-CoV-2 PCR positive and negative) underwent serologic testing for SARS-CoV-2 Spike (S1/S2) IgG (DiaSorin). DiaSorin IgG-positive results for patients that were SARS-CoV-2 PCR-negative were reflexed to nucleocapsid IgG (Abbott). Antibody testing occurred a median of 69 days (63–70 IQR) after PCR positivity.
Results
Nineteen SARS-CoV-2 PCR positive residents were identified from the outbreak and an additional 9 were transferred from the acute care hospital to the CRU; 1 died and 1 received convalescent plasma leaving 26 SARS-CoV-2 PCR positive residents, including 6 who were asymptomatic, that were eligible for serologic testing. Twenty-four of the 26 were positive for IgG by the DiaSorin assay; one seronegative resident was one of the asymptomatic residents. There were an additional 121 residents in the SNF whose SARS-CoV-2 PCR was negative at least once. Among these 121 SNF residents with negative SARS-CoV-2 RT-PCR, all but two were seronegative by the Diasorin assay. The two seropositive residents had no nucleocapsid antibodies when reflex tested by the Abbott assay.
Conclusion
In a limited sample of SNF residents with SARS-CoV-2 PCR positivity, the sensitivity of the Diasorin assay was 92% (24/26) and the specificity was 98% (119/121). None of the residents with negative SARS-CoV-2 PCR had confirmed positive antibody results using reflex testing (DiaSorin/Abbott). Despite high risk exposure in congregate living facilities, we found no evidence of additional SARS-CoV-2 exposure, reinforcing the importance of serial surveillance SARS-CoV-2 testing and early cohorting in SNF settings.
Disclosures
All Authors: No reported disclosures